PHYSIOTHERAPY ZONE » DIATHERMY / TECAR THERAPY » DIACARE 5000

  • DIACARE 5000
  • DIACARE 5000
  • DIACARE 5000
  • DIACARE 5000

DIACARE 5000

    • Id Product: 01319
    • Ref. manufacturer: G3488
    • Brand: GLOBUS

    Description:
    Resistive and Capacitive Energy Transfer. Heal the body taking advantage of our internal energy and the natural mechanisms of self-regeneration of tissues and muscles.

    En Stock 9.734,45 € 9.734,45 €

    Share

    • Extended description

      CATEGORY:

      Resistive and Capacitive Energy Transfer. Heal the body taking advantage of our internal energy and the natural mechanisms of self-regeneration of tissues and muscles.

      This is the fundamental principle of all philosophy that revolves around the world of therapy with the revolutionary new technique called diathermy or tecartherapy.

      The tecartherapy can work in two modes: the capacitive and resistive mode mode.

      DiaCaRe 5000 can work in both modes. Therefore the biological effect can be more effectively targeted tissues both higher strength (in practice tissues with lower water concentration) lower than those resistencia.DiaCare 5000 operating at a frequency of 470 KHz with an output 200 W ca - 400 VA T.V.

      Captrode: tailstock pole with three heads of different sizes and a return electrode for the capacitive mode. Included.

      Dualtrode: tailstock pole with three heads of different sizes and a return electrode for the resistive mode. Included.

      Monotrode: head all-in-one that leverages the traditional technique but in a simple way; in fact no need for the return electrode, because it is already contained in the same fixture. It is a bipolar spindle. Not included.

      personalized treatments: Particularly suitable for the treatment of shoulder problems, epicondyle, back, hip, ankle, muscles, joints.

      Beauty: Treatment of all skin imperfections, such as wrinkles, acne, alopecia, cellulitis, etc.Deporte: To reduce and prevent trauma during athletic training, promote recovery.

       

      Technical characteristics:

      - Power: 200W c.a. +/- 20% -outflows: 2
      - Headers: CapTrode, DualTro of
      - Transmission frequency:
      - Capacitive: 470 KHz
      - Resistive: 470 KHz
      - Radiating power: - Capacitive: 200W c.a.
      - 400VA T.V. - Resistive: 200W c.a.
      - T.V.-400VA Power supply: 220V 50/60 Hz
      - Dimensions: 17 x 22 x 6 cm Weight: 900 gr.
      - User Interface: Ergonomic Keyboard
      - Display: color touch
      - CE MDD Device Class II Strong BFPuntos and Technologies Globus
      - LCD screen, touch, a wireless remote control color-
      - Double navigation: touch screen and portable and lightweight gamepad-
      - Control patient tissue resistance

       

      Suitable for the treatment of:

      -Artrosis

      -Arthritis

      -Bursitis-Cervicalgia

      -Condromalacia

      contracturas

      -Condropatía-Sprain

      -Contraction

      Lesions

      -Luxación

      -Periartritis

      -Sciatica

      -Dislocation

      -Muscular stretch

      -Desgarro

      -Tendinitis

      Rehabilitation treatment of all acute and chronic bone and joint and muscle diseases.

      sports world: to reduce and prevent trauma during athletic training, to promote recovery.

       

      ENDOWMENT

      -1 Professional case

      1 unit DiaCare 5000

      -1 Capacitive CapTrode head with three heads Ø 30-50-70mm

      -1 DualTrode resistive head with three heads Ø 30-50-70mm

      -1 Counter plate

      -1 Manual

      -1 Cream container.

       

      TECARTHERAPY
      Energy to the site of injury is sent, the efficacy of this therapy is based on the possibility of transferring energy biocompatible injured tissues without Supplying from the outside towards the inside and inducing currents so-called displacement currents.

      These displacement currents are the biological response of the body fluids to alternating current, ie the continuous changes per second, which produces alternating current. Alternarnancias These can range from 500,000 times to 3,000,000 times per second this oscillation is the reciprocating movement of electrical charges, which in the form of ions are essential constituents of each biological substrate.

      Body repair process is activated and accelerated time before possible.

      The temperature increase is generated from inside the biostructure, the effect of displacement currents we mentioned before this temperature increase, also known as hyperthermia from the peripheral areas where the emitter electrode is applied is concentrated towards the application area .

      Projected energy will cross the different tissues to go to the receiver through electrode area preferably lower resistivity of the patient's body.

      Normally these air match injured areas that are more conductive electrical current due to the presence of electrolytes to enhance the flow of current, but on this trip densities of tissues, also generate some resistance in its path and them a certain amount of power is generated as heat. This unique mechanism of selective hyperthermia may be described as a controlled blood fever and localized benefits the patient the positive features of the fever, but without suffering their drawbacks nor contraindications are talking undoubtedly a powerful weapon cure human body through its own repair mechanisms.

      To understand it better if the body were a machine button auto repair serious fever, which provides a biological importance to its ability Tecarterpia this button activates auto body repair safely and without side effects.

       

      View Technical details

       

      TO SEE THE TREATMENT THAT YOU CAN USE CLICK HERE

       

    • Request of Information: